Art-Net Trigger

The player is controlled by ArtTrigger commands. See the latest version of the ArtNet specification for details of the exact message format.

OEMCode 0xFFFF is accepted through either unicast or broadcast ArtTrigger messages.

Key = 3, SubKey = showfile number (0 – 99)

Key = 2, SubKey = command (see table below)

 SubKey value (for Key = 2)  Command
 'B' (Hex 0x42) Blackout
 'G' (Hex 0x47) Start
 'R' (Hex 0x52) Resume
 'S' (Hex 0x53) Stop


Comments