All parameters are optional. They all have a defined default value.
The configuration is stored in the file "ldisplay.txt".
MAX7219
Parameter name
|
Description |
max7219_type |
matrix, 7segment (default = matrix) |
max7219_intensity |
0..15 (default = 4) |
WS28xx
Parameter name
|
Description |
led_type |
WS2801, WS2811, WS2812, WS2812B, WS2813, WS2815, SK6812, SK6812W, APA102, TLC59711, UCS1903, UCS2903 (default = WS2812B)
|
ws28xx_type |
matrix, 7segment (default = 7segment) | ws28xx_intensity | 1..255 (default = 255)
| ws28xx_colon_blink_mode | off, down, up (default = up)
| ws28xx_colour_segment | rrggbb in hex value (default = ff0000)
| ws28xx_colour_colon
| rrggbb in hex value (default = fffc00) | ws28xx_colour_message | rrggbb in hex value (default = ffffff) |
Example: #ldisplay.txt #ws28xx_type=7segment #led_type=WS2812B # Overwrite datasheet # #led_rgb_mapping=GRB # WS28xx # #ws28xx_intensity=255 #ws28xx_colon_blink_mode=up #ws28xx_colour_segment=ff0000 #ws28xx_colour_colon=fffc00 #ws28xx_colour_message=ffffff # MAX7219 # #max7219_type=matrix #max7219_intensity=4 # APA102 # #global_brightness=255
|
|